Abort Switch ABY
Yellow abort call point to hold discharge during the countdown.
Range image12 V DC monitoring panel with inbuilt hooter and flasher for pneumatic systems.
The master control unit supervises and annunciates a suppression system rather than releasing it electrically, which makes it the panel of choice for pneumatically actuated CDS and CIS installations where the cylinder fires itself.
Inbuilt hooter and flasher give local audible and visual alarm without separate sounders, and indicators show mains on, battery on, system healthy and gas released. A dry contact relay (C / NO / NC) passes the signal to plant shutdown or a building management system.
Housed in a powder coated mild steel box, mains supplied at 220 V AC with 12 V DC operation and battery backup, rated 0 to 50 °C.
Configuration review. Catalogue reference data for Master Control Unit MCU 1210 / MCU 1210A: Construction: Powder Coated Mild Steel Box; Power Supply: 220 V AC; Operating Nominal Voltage: 12 V DC. These values describe this product. Confirm the remaining interfaces and operating requirements against the system drawing and current manufacturer documentation.
Selection checks. Confirm the required cause-and-effect sequence and distinguish supervisory duties from electrical release control. Check every input and output type against the connected devices, including supervision, load and backup arrangements. Include the building interfaces and the agreed commissioning sequence with the enquiry.
Before ordering. For a Master Control Unit MCU 1210 / MCU 1210A quotation, provide the required quantity, installation or replacement context, and the associated equipment model. Include photographs or drawings of the interfaces and any project documentation requirements. Ask the supplier to identify the exact offered configuration and the scope of installation, commissioning or servicing included.
What buyers and engineers most often ask before specifying the Master Control Unit MCU 1210 / MCU 1210A.
Ask your own questionCatalogue reference data for Master Control Unit MCU 1210 / MCU 1210A: Construction: Powder Coated Mild Steel Box; Power Supply: 220 V AC; Operating Nominal Voltage: 12 V DC. These values describe this product. Confirm the remaining interfaces and operating requirements against the system drawing and current manufacturer documentation.
Confirm the required cause-and-effect sequence and distinguish supervisory duties from electrical release control. Check every input and output type against the connected devices, including supervision, load and backup arrangements. Include the building interfaces and the agreed commissioning sequence with the enquiry.
Send the project details. We’ll confirm the configuration and prepare a quote.
Red combined sounder and beacon, 18–24 V DC.
Range imageElectronic Components
Green manual release call point for immediate discharge.
Range imageElectronic Components
Sealed rechargeable 13 AH standby battery for extended autonomy.